IFI27L1 ELISA Kit (MBS2000899) | 루미젠코리아
MyBioSource
This assay has high sensitivity and excellent specificity for detection of Inter Sandwich ELISA Kits 24-Strip-Wells 2.743-2000pg/mL The standard curve concentrations used for the ELISA's were 2000pg/mL, 666.67pg/mL, 222.22pg/mL, 74.07pg/mL, 24.691pg/mL, 8.23pg/mL, 2.743pg/mL RT
제품 사양
| Cat No | MBS2000899 |
|---|---|
| Manufacturer | MyBioSource |
| Reactivity | This assay has high sensitivity and excellent specificity for detection of Inter |
| Target | IFI27L1 |
| Assay Method | Sandwich |
| Size | 24-Strip-Wells |
| Detection Range | 2.743-2000pg/mL The standard curve concentrations used for the ELISA's were 2000pg/mL, 666.67pg/mL, 222.22pg/mL, 74.07pg/mL, 24.691pg/mL, 8.23pg/mL, 2.743pg/mL |
| Sensitivity | The minimum detectable dose of this kit is typically less than 11.8pg/mL |
| Sample Type | Tissue homogenates and other biological fluids |
| Storage | RT |
Datasheet PDF Provided by MyBioSource
상세 설명
IFI27L1(인터페론 알파 유도 단백질 27 유사체 1)은 분자 어댑터 활성을 가진 것으로 예측되며, 미토콘드리아 막에 위치하여 세포 사멸(apoptosis) 과정에 관여하는 단백질입니다. 인터페론 신호전달 경로 및 미토콘드리아 기반 세포사멸 연구에 활용 가능하며, 본 ELISA 키트로 고감도 정량 분석이 가능합니다. 루미젠코리아를 통해 구매하실 수 있습니다.
ELISA kit for IFI27L1 (Interferon Alpha Inducible Protein 27-Like 1) detection. Mitochondrial membrane-associated protein with molecular adaptor activity; involved in apoptosis. 24-strip-well format.
타겟 유전자 정보 — IFI27L1
분자 어댑터 활성을 가능하게 할 것으로 예측됩니다. 세포자멸사 과정에 관여합니다. 막에 위치할 것으로 예측됩니다. 미토콘드리아 막에서 활성 상태일 것으로 예측됩니다.
출처: NCBI Gene Database
관련 질환
basophil measurement Abruptio Placentae pulse wave reflection index measurement retinitis pigmentosa Familial exudative vitreoretinopathy
출처: Open Targets 25.12, PubMed 2026-03 기준
연구 동향
PubMed 등록 논문 5편 (최근 5년 5편)
출처: Open Targets 25.12, PubMed 2026-03 기준
Interferon Alpha Inducible (MBS2000899)은 루미젠코리아를 통해 국내 구매 및 견적이 가능합니다.
제조사: MyBioSource | 분류: ELISA Kits
보관 조건: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. | 배송 조건: –
제조사: MyBioSource | 분류: ELISA Kits
보관 조건: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. | 배송 조건: –